Saturday, April 15, 2017

Checking Operation system certificate in obiee11g installation error


Checking Operation system certificate in obiee11g installation error






I faced the above issue while installing OBIEE11g in my local machine.

Issue:
OBIEE 11g 11.1.1.7.0 was recently certified on Windows Server 2012 64‑bit. When installing, the pre‑requisite check for the Operating
System fails.
Cause:
The software is certified; however, the Oracle Installer is not yet updated to reflect the certification. This can sometimes occur when a
certification happen post software release.

Resolution:
You can resolve this error by updating the pre‑requisite check file in the install media.
Step 1:
Navigate to where you have unzipped, with 7‑zip, the OBIEE 11g (11.1.1.7.0) installation media (locally or on a mount).
Step 2:
Backup the following file:
bishiphome\Disk1\stage\prereq\win64\refhost.xml
Step 3:
Update the refhost.xml file to add the new operating system at the end of the certified systems section




Step 4: Save the file
Step 5: Re‑start the Installer to re‑start and complete the install.
Step 6: The installer will then proceed without the error.

Thanks 

No comments:

Post a Comment

 BEST PYSPARK LEARNING SITES https://www.youtube.com/watch?v=s3B8HXLlLTM&list=PL2IsFZBGM_IHCl9zhRVC1EXTomkEp_1zm&index=5 https://www...